ClickCease
Request Quote

HVA45TD

VLF/DC Hipot Tester with Integrated Tan Delta

This unit packs a punch at 45kV peak output and integrated Tan Delta. There is no need to have a separate external Tan Delta instrument with this all-in-one design. Fully compliance with the IEEE400, 400.2, IEC 60502, CENELEC HD620/621 guides and standards. At only 86 lbs / 39 kg this unit is very portable, housed in a rugged IP67 case.

With a high test capacity of 10uF, there are very few loads or cables this instrument cannot test. With the a large 4.3" color display, automatic TD evaluation, and manual and automatic test functionality, DC and AC operation, testing in the field just got a whole lot easier.

Designed for performing diagnostic testing for up to 35kV rated cables and full acceptance testing of cables 25kV and lower, this unit covers most of the MV cables installed today. All instruments are shipped with a NIST calibration certificate, TD Control Center software, corona protection shields, Bluetooth dongle, and accessories tote.

Features:

  • Pure AC VLF, and DC (+ or - polarity)
  • Load independent sinusoidal 0.1Hz
  • Integrated TD
  • TD Resolution ±1x10-4
  • TD Analysis & Reporting using TD Control Center
  • Digital RMS metering
  • Smallest compact rugged construction
  • Bluetooth/USB Mem. stick PC Interface
  • 4.3" Color LCD Display
  • Weighs only 86 lbs / 39 kg
  • Insulation Resistance & Cap. Measurement
  • Perform advanced diagnostics on MV Cables acc. to IEEE400, 400.2, CENELEC HD620/621
  • Output Frequency optimization
  • Real time oscilloscope display
  • Auto & Manual Test programmable Sequences
  • Internal Storage of Test Reports
  • Unlimited duty cycle
  • Flashover voltage detection
  • Power supply immunity and independence
  • Low maintenance, oil-free design
  • RMS Digital Metering of Current and Voltage
  • Automatic TD Evaluation
  • Vacuum Bottle Test functionality
  • Optional Partial Discharge Interface

Output Modes

  • VLF 32kVrms/45kV Peak output
  • DC ±45kV
  • Sine/Square/ DC outputs
  • Cable Jacket / Sheath testing mode
  • TD measurement mode
  • Vacuum bottle testing mode
  • Fault Conditioning/Trip
  • Load independent output waveform

Safety

  • Short circuit detection
  • Emergency Off Interlock
  • Integrated internal discharge of DUT.
  • 12kV power frequency voltage feedback protection


Optional Attachments

Technical Specifications

Ordering Information:
745 001
Power Supply/Input Voltage:
110 to 240V AC ±10% (50/60Hz)
Input Power Requirements:
1.2kVA
Rated Max Output Voltage:

Sinusoidal RMS/Peak
32kV / 45kV
Squarewave
45kV
DC
± 0-45 kV
Accuracy
± 1%, Resolution: 0.1 kV
Output Current:
0-60 mA, Accuracy: ± 1%, Resolution: 1 µA
Resistance Range:
0.1 MΩ - 20 GΩ
Output Frequency (default 0.1Hz):
0.01-0.1 Hz in Steps of 0.01 Hz (default 0.1 Hz)
Automatic Frequency Optimization
Output Load:
1 µF @ 0.1 Hz @ 32 kVrms10.0 µF @ 0.01 Hz @ 32 kVrms10.0 µF Maximum Capacitance*
Sheath Test:
Max Test Voltage: 10 kV | Trip Current: 0.1 mA - 5.0 mA
Sheath Fault Location:
Max Test Voltage: 10 kV | Pulse/Period: 1:3 / 4 s, 1:5 / 4 s, 1:5 / 6 s, 1:9 / 6 s
Metering:
Voltage and Current (True RMS and / or Peak), Tan Delta Capacitance, Resistance, Time, Flashover Voltage
Tan Delta Measurement:
Accuracy ± 1 x 10-4. Fully Compliant with IEEE400.2
Duty Cycle:
Continuous
Test Modes:
Manual & Automatic
Output Modes:
AC (VLF) Sinewave Symmetrical and Load-Independent Across Full Range, DC (Plus orNegative Polarity), Burn/Fault Condition or Fault Trip Mode, Jacket/Sheath Testing, Squarewave
Safety:
50 / 60 Hz - 12kV Feedback Protection / Dual Discharge System (internal)
Computer Interface:
Bluetooth and USB
Memory / Test Record Storage:

Built in Memory
50 Test Records, 50 Test Sequences
USB Flash Drive
Unlimited (see options)
PC Software
“HVA Control Center” and “TD Control Center” Windows Compatible
Standard HV Test Lead Cable Included:
13ft / 4m
Weight:
86 lbs / 39 kg
Dimensions:

Imperial (inches)
19.7 x 12 x 18"
Metric (mm)
500 x 305 x 457 mm
Environmental:
-13°F to 158°F / -25°C to 70°C
23°F to 113°F / -5°C to +45°C
85% RH non-condensing

* Based on typical MV cable. 100pf/ft or 330 pF/m

Note: Due to continuous development, the information may change without notice.

VLF / DC
Tan Delta
TD
Partial Discharge
PD
Oil
Testing
Cable
ID
Fault
Location