VLF / DC Hipot Tester

The model HVA90 and HVA94 offer customers the ability to test MV and Sub Transmission class cables including 69kV and 46kV cable and below. The lightest 90kV VLF/DC system on the market, this single instrument not only produces some of the highest VLF AC voltages available, but it also has a very powerful output capability. This facilitates the testing of long cables.

Like all models in the HVA series, the user interface is the same. This means that any operator who is familiar to operating a HVA34 for example, can also operate the HVA90/94. Setup is simple and automatic with no cumbersome interconnecting of various modules.

Automatic test sequences, like on all HVA models can be setup directly on the instrument or on the supplied HVA Control Center software. Test reports are downloaded to the instrument’s internal memory or to a USB flash drive.

Features:

  • Tests your MV and Transmission cable networks
  • Test up to 10µF (100,000ft/30kms)
  • Single Piece Design
  • Weighs only 280 lbs / 127kg
  • Perform tests fully automatically
  • Real time oscilloscope display
  • RMS Metering of Current and Voltage
  • Output Frequency optimization
  • Insulation Resistance & Cap. measurement
  • Internal Storage of Test Reports
  • Download to PC and / or USB flash drive
  • Unlimited duty cycle
  • Bright backlit LCD display
  • Power supply immunity and independence
  • Low maintenance, oil-free design
  • HVA Control Center – User friendly software for immediate, professional detailed reporting and setup
  • Free HVA Control Center Software and upgrades

Output Modes

  • High voltage 90kV (HVA90) or 94kV output (HVA94)
  • DC ±90/94kV
  • VLF Sinewave / Squarewave & DC outputs
  • Cable Jacket / Sheath testing
  • Vacuum bottle testing
  • Fault Conditioning / Fault Trip
  • Load independent output waveform

Safety

  • Integrated internal discharge of DUT
  • 12kV power frequency voltage feedback protection
  • Flashover voltage detection
  • Remote interlock “kill switch” and HV status indication
  • Short circuit detection
  • Local Emergency off button


Optional Attachments

Technical Specifications

Ordering Information:
709 001
Power Supply/Input Voltage:
110 to 240V AC ±10% (50/60Hz)
Input Power Requirements:
1.5kVA
Rated Max Output Voltage:

Sinusoidal RMS/Peak
64kV / 90kV
Squarewave
90kV
DC
±90kV
Rate Max Output Current:

Sinusoidal RMS
45mA
DC/Squarewave
65mA
Output Frequency (default 0.1Hz):
0.01Hz to 0.1Hz adjustable small increment of 0.01Hz (10 frequencies)
Frequency Optimization:
Yes
Maximum Output Load Capability @ MAXIMUM voltage and frequency:
1 µF
*10,000ft
*3km
Maximum Output Load Capability @ REDUCED voltage and/or frequency:
10 µF
*100,000ft
*30km
Metering:

Voltage
0.1kV Resolution ±1% Accuracy
Current
1 µA Resolution ±1% Accuracy
Capacitance
0.1 nF to 20 µF Range
Resistance
0.1MΩ to 20GΩ Range
Timing
Included and integrated
Fast Arc/Flashover
Detection included and integrated
Waveform
Real time oscilloscope display of actual output voltage waveform
Output Mode (all load independent & symmetrical):
VLF AC Sinewave
VLF AC Squarewave
DC (both Positive and Negative Polarity)
Fault Condition Mode / Fault Trip Mode
Vacuum Bottle Test Mode (DC) - optional
Cable Jacket / Sheath Test Mode
Output Duty:
Continuous
Computer Interface:
RS232 Standard, USB Flash Memory Download Module (optional)

HVA Control Center Software included with every HVA instrument
Memory / Test Record Storage:

Built in Memory
50 Test Records
USB Flash Drive
Unlimited (see options)
No. of programmable Automatic Test Sequences:
40
Standard HV Test Lead Cable Included:
50ft / 15m
Weight:
280 lbs / 127 kg
Dimensions:

Imperial (inches)
26 x 17.5 x 24"
Metric (mm)
650 x 445 x 610 mm
Environmental:

Storage
-13°F to 158°F / -25°C to 70°C
Operating
23°F to 113°F / -5°C to +45°C
Humidity
85% RH non-condensing

* Based on typical MV cable. 100pf/ft or 330 pF/m