ClickCease
Request Quote

TD30

Tan Delta Diagnostics System

The TD30 was the first small portable VLF TD system with wireless Bluetooth technology that really made performing Tan Delta testing in the field easy to perform. Compared to other TD systems on the market that required several connections to be made or were large and bulky, the TD30 requires very few connections and does not use any special batteries or fiber optic cabling that is prone to damage in the field environment.

The TD30 is designed to work with the HVA30, HVA30-7 and HVA34 VLF test systems making it suitable for testing 25kV and below cable systems. The unit is supplied with host of accessories including corona protection, Blue tooth dongle, jumper cable, ground cable, C Type batteries, C Battery Charger etc.

VLF Power Supply Required - Sold Separately


Features:

  • Perform advanced diagnostics on MV Cables according to IEEE400 and 400.2
  • Suitable for testing 25kV cables and below
  • Wireless Bluetooth Connection
  • Minimum connection hookups
  • Accurate 1E-5 Resolution!
  • Excellent, easy to use TD reporting
  • Supplied with Free TD control center Software and FW upgrades
  • Local LED indication for TD value range
  • Leakage Current Guard Protection
  • Sleep mode saves battery life
  • Uses universal C-type batteries
  • Supplied in rugged transport case with all accessories.

Measurements / Software

  • Info coming soon


Compatible VLF Hipots

Technical Specifications

Ordering Information:
700 003
Power Supply:
2 C Type Batteries
Rated Operating Voltage:

RMS
1-23kV
Peak
33kV
Voltage Measurement:

Resolution
0.1kV
Accuracy
1% (of reading)
Current: Measurement

Resolution
1µA
Accuracy
1% (of reading)
Frequency Measurement

Range
0.01 to 0.1Hz
Resolution
0.01Hz
Tan Delta / Dissipation Factor Measurement:

Resolution
1 x 10
-5
Accuracy >15nF
±1 x 10
-4
Accuracy <15nF
±3 x 10
-4
Minimum Load:
5nF
Weight:

7 lbs / 3 kgs
Dimensions:

(Length x Diameter)
9.5 x 3.5 inches / 240 x 85mm
Computer Interface:
Bluetooth™
Accessories Included:
Integrated HV and Grounding Cable
Bluetooth USB Dongle
TD Control Center Software
Operating Manual
Corona Protection
Standards:

Shock
IEC68-2-27
Vibration
IEC68-2-6
EMC
IEC6100-4-2, IEC6100-4-4, EN55011
Safety
EN60950, EN50191, EN61010-1
Environmental:

Storage
-13°F to 158°F / -25°C to 70°C
Operating
23°F to 113°F / -5°C to +45°C
Humidity
80% RH non-condensing

Note: Due to continuous development, the information may change without notice.

VLF / DC
Tan Delta
TD
Partial Discharge
PD
Oil
Testing
Cable
ID
Fault
Location