ClickCease
Request Quote

HVA34

VLF/DC Hipot Tester

This model replaces the ground breaking and very popular model HVA30. The HVA30 was upgraded to the HVA34 to accommodate the new testing requirements for 25kV rated cables as per the latest revision of IEEE400.2 testing standard.

Arguably the top selling VLF/DC instrument on the market, this instrument has become the standard for testing 25kV rated cables and below. The upgraded model includes an even more powerful output while keeping the same overall weight, physical dimensions, and user interface.

A single piece design, weighting only 44 lbs / 19.5kgs, it is capable of testing up to 120, 000ft / 37km of cable. This is not just a VLF hipot, it also includes a DC hipot, Fault conditioning, Sheath testing, and Vacuum Bottle testing modes all housed in single piece, powerful test instrument.

Features:

  • Test your 25 (Maint), 15, 11, 8, 6.6, 5kV long MV cables
  • Weighs only 44lbs / 19.5kg
  • Perform tests fully automatically
  • Oscilloscope Display of Output Waveform
  • Insulation Resistance & Cap. Measurement
  • RMS Metering of Current and Voltage
  • Output Frequency optimization
  • Internal Storage of Test Reports
  • Download to PC and / or USB flash drive
  • Unlimited duty cycle
  • Flashover voltage detection
  • Bright backlit LCD display
  • Power supply immunity and independence
  • Low maintenance, oil-free design

Output Modes

  • VLF Sinewave / Squarewave & DC outputs
  • VLF 24kVrms / 34kVpk output
  • DC ±34kV
  • Cable Jacket / Sheath testing
  • Vacuum Bottle testing

Safety

  • Integrated internal discharge of DUT
  • Short circuit detection
  • 12kV power frequency voltage feedback protection
  • Remote interlock “kill switch” and HV status indication


Optional Attachments

Technical Specifications

Ordering Information:
734 001
Power Supply/Input Voltage:
110 to 240V AC ±10% (50/60Hz)
Input Power Requirements:
400VA
Rated Max Output Voltage:

Sinusoidal RMS/Peak
24kV/34kV
Squarewave
34kV
DC
±34kV
Rate Max Output Current:

Sinusoidal RMS
10mA
DC/Squarewave
14.5mA
Output Frequency (default 0.1Hz):
0.01Hz to 0.1Hz adjustable small increment of 0.01Hz (10 frequencies)
Frequency Optimization:
Yes
Maximum Output Load Capability @ MAXIMUM voltage and/or frequency:
0.5 µF
*120,000ft
*37km
Maximum Output Load Capability @ REDUCED voltage and/or frequency:
12 µF
*120 000ft
*37km
Metering:

Voltage
0.1kV Resolution ±1% Accuracy
Current
1 µA Resolution ±1% Accuracy
Capacitance
0.1 nF to 20 µF Range
Resistance
0.1MΩ to 20GΩ Range
Timing
Included and integrated
Fast Arc/Flashover
Detection Included and Integrated
Waveform
Real time oscilloscope display of actual output voltage waveform
Output Mode (all load independent & symmetrical):
VLF AC Sinewave
VLF AC Squarewave
DC (both Positive and Negative Polarity)
Fault Condition Mode / Fault Trip Mode
Vacuum Bottle Test Mode (DC) - optional
Cable Jacket / Sheath Test Mode
Output Duty:
Continuous
Computer Interface:
RS232 Standard, USB Flash Memory Download Module (optional)

HVA Control Center Software included with every HVA instrument
Memory / Test Record Storage:

Built in Memory
50 Test Records
USB Flash Drive
Unlimited (see options)
No. of programmable Automatic Test Sequences:
40
Standard HV Test Lead Cable Included:
13ft / 4m
Weight:
44 lbs / 20 kg
Dimensions:

Imperial (inches)
17 x 14 x 10"
Metric (mm)
430 x 360 x 250 mm
Environmental:

Storage
-13°F to 158°F / -25°C to 70°C
Operating
23°F to 113°F / -5°C to +45°C
Humidity
85% RH non-condensing

* Based on typical MV cable. 100pf/ft or 330 pF/m

Note: Due to continuous development, the information may change without notice.

VLF / DC
Tan Delta
TD
Partial Discharge
PD
Oil
Testing
Cable
ID
Fault
Location